The Sol-Ark Whole Home 15K-2P is a residential all-in-one hybrid inverter designed to back up an entire home. With 200A of grid pass-through it can be installed ahead of your main panel, so every circuit stays powered during an outage, not just a critical-loads subpanel. It integrates the solar inverter, three MPPT charge controllers, a 48V battery inverter/charger and an automatic transfer switch in one outdoor-rated enclosure.
The 15K-2P keeps producing power through prolonged grid outages, manages your battery and grid use around time-of-use rates, and scales up to 12 units in parallel as your needs grow.
Highlights
-
15,000W continuous AC output (12,000W / 50A at 240V from batteries alone)
-
24,000VA surge for 10 seconds (30,000VA for 100ms) for HVAC, well pumps and motors
-
19,500W of solar input on 3 full-size MPPTs with 6 DC solar ports
-
200A grid pass-through for true whole-home backup
-
275A battery charger with two 48V battery ports
-
5ms automatic transfer with a built-in transfer switch
-
Stackable: up to 12 units in parallel
-
IP65 / NEMA 3R outdoor enclosure, 10-year standard warranty
Whole-Home Backup & Grid Connection
- 200A pass-through and a 200A integrated AC output breaker for whole-home installations
- 120/240V split phase, 120/208V or 220V configurable, 50/60Hz
- Adjustable power factor (±0.9); listed to UL 1741 SB, CA Rule 21 and HECO Rule 14H for grid-interactive systems
Solar Input
- Up to 19,500W of PV (STC) across 3 MPPT trackers, 2 strings per tracker (6 DC solar ports)
- MPPT range 150–500V (175–425V rated), 125V start-up, 500V max input
- 26A operating / 44A short-circuit current per MPPT
- Up to 19,200W of AC-coupled input to integrate an existing grid-tie system
- Integrated rapid shutdown controls, arc-fault detection, ground-fault detection and PV DC disconnect
Battery Compatibility
- 48V nominal (43–63V operating range), 50–9,900Ah bank capacity
- 275A max charge/discharge with 2 × 200A battery disconnects
- DC-to-DC battery architecture that Sol-Ark says improves battery efficiency and extends battery life
- Closed-loop CANBus and RS485 Modbus BMS communication; works with lithium or lead-acid
- 3-stage charging with equalization, 96% grid-to-battery efficiency, battery temperature sensor included
Sol-Ark lists Briggs & Stratton Energy Solutions, Discover Energy Systems, Pytes USA and Renon Power as certified battery partners, and offers UL 9540 battery upgrade options.
Generator Integration
- Dedicated generator (GEN) input with integrated 2-wire automatic generator start
- Single-circuit Smart Load output
- Can also power and charge EVs from your solar and battery system
Monitoring & Smart Energy Control
-
Wi-Fi and LAN hardware included for remote monitoring through the MySolArk app and installer platform, hosted on US-based servers
-
On-inverter LCD touchscreen for programming without a laptop
-
Built-in Time-of-Use (TOU) control with multi-season, day-of-week and time-of-day schedules to store solar and avoid peak-rate grid power
-
NEM 3.0 ready and Virtual Power Plant (VPP) ready for utility demand-response programs
EMP Hardened Option
Select EMP Hardened: Yes for Sol-Ark's 2X military-grade EMP option, a factory-hardened 15K-2P designed to keep operating after electromagnetic pulse events such as severe solar storms and lightning strikes. Sol-Ark states the EMP-hardened 15K-2P meets and exceeds the MIL-STD-461G standard; the test report is linked below. Ratings and specifications are otherwise the same as the standard model.
Full Specifications
| PV Input |
| Max PV power (STC) |
19,500W |
| MPPT voltage range |
150–500V (175–425V rated) |
| Start-up voltage |
125V |
| Max DC input voltage |
500V |
| Max operating current per MPPT |
26A |
| Max short-circuit current per MPPT |
44A |
| MPP trackers / strings |
3 trackers, 2 strings each |
| Max AC-coupled input |
19,200W |
| AC Output |
| Nominal voltage |
120/240V, 120/208V, 220V |
| Frequency |
50/60Hz |
| Max continuous power |
15,000W |
| Max continuous power (batteries only) |
12,000W (50A @ 240V) |
| Max output current |
62.5A |
| Peak power (off-grid, 240V) |
24,000VA for 10s / 30,000VA for 100ms |
| Max output fault current |
94A with PV / 75A batteries only (5s); 120A (100ms) |
| Max grid pass-through |
200A |
| Power factor |
±0.9 adjustable |
| Backup transfer time |
5ms |
| Design |
Transformerless DC-to-AC |
| Parallel |
Up to 12 units |
| Battery (DC) |
| Battery types |
Lithium, lead-acid |
| Nominal voltage |
48V (43–63V range) |
| Capacity |
50–9,900Ah |
| Max charge/discharge current |
275A |
| Battery disconnect |
200A per pole, ×2 |
| Charging |
3-stage with equalization |
| Grid-to-battery efficiency |
96.0% |
| Battery temp sensor |
Included |
| Generator auto-start |
2-wire, integrated |
| BMS communication |
CANBus & RS485 Modbus |
| Efficiency |
| CEC efficiency |
96.5% |
| Max efficiency |
97.5% |
| General |
| Dimensions (H×W×D) |
31.8 × 19.4 × 12 in (807 × 494 × 306 mm) |
| Weight |
135 lb (61.2 kg) |
| Enclosure |
IP65 / NEMA 3R |
| Operating temperature |
-13°F to 131°F (-25°C to 55°C), derating above 113°F |
| Noise |
<30 dB |
| Idle consumption |
90W |
| Communication |
Wi-Fi & LAN hardware included |
| Warranty |
10 years standard |
| Protection & Certifications |
| Certifications |
UL 1741-2010/2018, UL 1741 SB, IEEE 1547a-2003/2014, FCC 15 Class B, CA Rule 21, HECO Rule 14H |
| PV DC disconnect (NEC 240.15) |
Integrated |
| Ground fault detection (NEC 690.5) |
Integrated |
| Rapid shutdown (NEC 690.12) |
Integrated |
| Arc fault detection (NEC 690.11) |
Integrated |
| PV lightning protection |
Integrated |
| PV reverse polarity protection |
Integrated |
| AC output breaker |
200A, integrated |
| Surge protection |
DC Type II / AC Type II |
Downloads